AbstractThomson scattering; systems diagnosing three regions of the large helical device (LHD) are presented. (1) An obliquely back-scattered Thomson scattering system gives full profiles of electron temperature (Te) and density (ne) along the major radius on the mid-plane with a spatial resolution of 1.5–4.0 cm. A piezo-actuated mirror is dynamically oriented so that the beams from ten 50 Hz repetition rate Nd:YAG lasers propagate a common path along a major radius, giving Te and ne profiles every 2 ms. (2) A cavity Thomson scattering system will measure two-dimensional Te and ne profiles along the laser beam propagating off-axially right and left in an optical cavity. This will diagnose the island structures in the outer edge region. (3) A fiber Thomson scattering system, in which laser light is guided by an optical fiber, is freely movable and conveniently used to probe the diverted plasma.
大型ヘリカル装置(LHD)における3つの領域を診断するトムソン散乱システムを紹介する。(1) 斜め後方散乱トムソン散乱システムは、主平面上の大半径方向に沿って電子温度(Te)と密度(ne)の全体プロファイルを、1.5~4.0cmの空間分解能で提供する。圧電アクチュエータ駆動ミラーを動的に方向制御することで、10Hzの繰り返し周波数を持つ10台のNd:YAGレーザーからのビームが大半径方向に沿って共通の経路を伝搬し、2msごとにTeとneのプロファイルを得る。(2) キャビティトムソン散乱システムは、光共振器内を非軸方向に右および左へ伝搬するレーザービームに沿って、2次元のTeとneプロファイルを測定する。これにより、外側周辺領域における磁気島構造を診断する。(3) 光ファイバーを用いてレーザー光を導波するファイバートムソン散乱システムは、自由に移動可能であり、ダイバータプラズマの計測に好適である。