Improving tokamak vertical position control in the presence of power supply voltage saturation

J-Y Favez, J B Lister, Ph Müllhaupt, B Srinivasan2005年Plasma Physics and Controlled FusionIF 2.2出版社

The control of the current, position and shape of an elongated cross-section tokamak plasma is complicated by the so-called instability of the current vertical position. Linearized models all share the feature of a single unstable eigenmode, attributable to this vertical instability of the plasma equilibrium movement, and a large number of stable or marginally stable eigenmodes, attributable to zero or positive resistance in all other model circuit equations. Due to the size and therefore cost of the ITER tokamak, there will naturally be smaller margins in the poloidal field coil power supplies, implying that the feedback control will experience actuator saturation during large transients due to a variety of plasma disturbances. Current saturation is relatively benign, due to the integrating nature of the tokamak, resulting in a reasonable time horizon for strategically handling the approach to saturation which leads to the loss of one degree of freedom in the feedback control for each saturated coil. On the other hand, voltage saturation is produced by the feedback controller itself, with no intrinsic delay. This paper presents a feedback controller design approach which explicitly takes saturation of the power supply voltage into account when producing the power supply demand signals. We consider the vertically stabilizing part of the ITER controller (fast controller) with one power supply and therefore a single saturated input. We consider an existing ITER controller and enlarge its region of attraction to the full null controllable region by adding a continuous nonlinearity into the control. In a system with a single unstable eigenmode and a single stable eigenmode we have already provided a proof of the asymptotical stability of the closed loop system, and we have examined the performance of this new continuous nonlinear controller. We have subsequently extended this analysis to a system with a single eigenmode and multiple stable eigenmodes. The method requires state feedback control, and therefore a reconstruction of the states is indispensable. We discuss the feasibility of extracting these states from the available diagnostic information as well as other implementation details. As a complement to our ITER simulations we confirm the enlargement of the region of attraction by the new controller by a JET simulation.

装置

iter中精度(概要文一致)jet中精度(概要文一致)

wiki

Power supply
この論文にはまだAI要約がありません。

関連論文

Using LQR controller for vertical position control on EAST

2024Nuclear Fusion

Stability conditions of feedback control system of vertical plasma position in tokamaks with a resistive shell

1983Nuclear Fusion

First-principles-driven model-based current profile control for the DIII-D tokamak via LQI optimal control

2013Plasma Physics and Controlled Fusion

Toroidal current profile control during low confinement mode plasma discharges in DIII-D via first-principles-driven model-based robust control synthesis

2012Nuclear Fusion

Stability limit of feedback control of vertical plasma position in the JFT-2M tokamak

1987Nuclear Fusion

Effects of control voltage saturation and sensor noise on the resistive wall mode feedback in ITER

2019Nuclear Fusion

Feedback stabilization of axisymmetric modes in the TCV tokamak using active coils inside and outside the vacuum vessel

1998Nuclear Fusion

Multimode observations and 3D magnetic control of the boundary of a tokamak plasma

2013Nuclear Fusion

Effects of plasma deformability on the feedback stabilization of axisymmetric modes in tokamak plasmas

1992Nuclear Fusion

Active feedback stabilization of high beta modes in advanced tokamaks

2001Nuclear Fusion