AbstractThe safety study performed until December 2001 to assess the collective dose to the workers based on the International Thermonuclear Experimental Reactor (ITER) Fusion Energy Advanced Tokamak (FEAT) project, is presented in this work together with the relevant results. All systems located in the tokamak building of ITER FEAT facility important from the radiological point of view are considered. Radiological source terms with an important collective dose impact are airborne tritium and activated corrosion products (ACP) in the coolant of the water cooling system (WCS). A suitable computer code is used to assess the ACP inventory in the different WCS components. The dose rate is then assessed by considering walls attenuation with the 3D transport code MCNP, a Monte Carlo code that performs gamma ray transport calculation. Working activities needed to operate, maintain and replace each component of systems under study are partly provided by system designers and partly derived from the experience developed in operating nuclear fission reactors. In conclusion the collective dose result is shown and partly compared with that of previous ITER design stages considering the different systems and solutions and pointing out ALARA improvements.
2001年12月までに実施された安全評価研究は、国際熱核融合実験炉(ITER)核融合エネルギー先進トカマク(FEAT)計画に基づく作業者の集団線量を評価するものであり、本論文ではその結果とともに提示する。ITER FEAT施設のトカマク建屋に設置され、放射線学的観点から重要と考えられる全システムを対象とする。集団線量に大きな影響を与える放射線源項は、水冷却システム(WCS)の冷却材中に含まれる空中トリチウムおよび活性化腐食生成物(ACP)である。WCSの各構成要素におけるACPインベントリの評価には、適切な計算コードを用いる。次に、ガンマ線輸送計算を実施するモンテカルロコードである3次元輸送コードMCNPを用いて、壁による減衰を考慮した線量率を評価する。対象システムの各構成要素の運転、保守、交換に必要な作業活動は、システム設計者から提供されたものと、核分裂炉の運転経験から導出されたものの両方に基づく。結論として、集団線量の評価結果を示し、異なるシステムと設計解決策を考慮した上で、過去のITER設計段階の結果と比較し、ALARAの改善点を指摘する。