The global energy confinement of combined ohmic and lower hybrid driven TORE SUPRA plasmas has been analysed at various densities. In contradiction to the L mode ITER scaling law, this analysis indicates that the global energy confinement time depends strongly on the plasma density. Furthermore, the thermal electron energy content of steady state discharges is found to be in good agreement with the global Rebut-Lallia-Watkins (RLW) scaling law. Current ramp experiments show an enhancement of the global energy confinement with the internal inductance, li. These results have been extended to steady state regimes with lower hybrid current drive. Improved confinement has been obtained in a high li steady state plasma (li=1.7), where the modification of the current profile by lower hybrid waves leads to an increase in the central value of the safety factor (qψ(0) ≈ 2). In this case, the global confinement time is shown to exceed the value predicted by the RLW scaling law by 40%
オーミック加熱および低域混成波駆動によるTORE SUPRAプラズマの全体エネルギー閉じ込めを、様々な密度において解析した。ITERのLモードスケーリング則に反して、この解析は全体エネルギー閉じ込め時間がプラズマ密度に強く依存することを示している。さらに、定常状態放電における熱電子エネルギー含有量は、Rebut-Lallia-Watkins(RLW)全体スケーリング則と良好な一致を示すことが明らかになった。電流ランプ実験では、内部インダクタンスliの増加に伴う全体エネルギー閉じ込めの向上が観測された。これらの結果は、低域混成波電流駆動を伴う定常状態領域に拡張された。高いliを有する定常状態プラズマ(li=1.7)においては、改善された閉じ込めが達成され、低域混成波による電流分布の修正により、安全係数の中心値が増加する(qψ(0) ≈ 2)。この場合、全体閉じ込め時間はRLWスケーリング則による予測値を40%上回ることが示された。