The feedback control system to control plasma current and position on the HT-7 superconducting tokamak was greatly improved in early1998. Lower hybrid current drive (LHCD) experiments with the improved control system were performed to sustain long pulse discharges and to improve plasma confinement. Partial non-inductive current drive and full non-inductive current drive for several seconds by means of LHCD were demonstrated. It was observed that plasma confinementcould be considerably improved by LHCD. Experimental evidence suggests that this improvement during the LHCD phase could be due to the modification of the current profile in the outer region of the plasma. MHD modes (especially m = 2) seem unstable with such a current profile. The EFIT code was modified for the reconstruction of the magnetic surfaces in HT-7 and a test computation was performed.
HT-7超伝導トカマクにおけるプラズマ電流および位置のフィードバック制御システムは、1998年初頭に大幅に改良された。改良された制御システムを用いた低域混成波電流駆動(LHCD)実験は、長時間パルス放電の維持とプラズマ閉じ込めの改善を目的として実施された。LHCDによる部分的な非誘導電流駆動および数秒間の完全な非誘導電流駆動が実証された。LHCDによってプラズマ閉じ込めがかなり改善され得ることが観測された。実験的証拠は、LHCDフェーズ中のこの改善が、プラズマ外部領域における電流分布の修正に起因する可能性があることを示唆している。このような電流分布では、MHDモード(特にm=2)が不安定になると思われる。HT-7における磁気面の再構成のためにEFITコードが修正され、試験計算が実施された。