With the dynamic ergodic divertor in TEXTOR fundamental effects of the coupling of external magnetic field perturbations to the confined plasma have been studied. The non-linear coupling between external (m/n = 12/4) and internal modes (m/n = 3/1) has been investigated. The critical perturbation field (m/n = 3/1) for the excitation of an m/n = 2/1 tearing mode depends not only on the magnitude but also on the direction of the toroidal angular momentum input by neutral beam injection (NBI). Below the excitation threshold of this mode a toroidal spin-up of the plasma has been observed, which only depends on the strength of the perturbation field. It is independent of both the rotation direction of the external perturbation field and the toroidal angular momentum supplied by the NBI.
TEXTORの動的エルゴディックダイバータを用いて、外部磁場摂動の閉じ込めプラズマへの結合の基本的効果が研究されてきた。外部モード (m/n = 12/4) と内部モード (m/n = 3/1) の間の非線形結合が調査された。m/n = 2/1 テアリングモードの励起のための臨界摂動場 (m/n = 3/1) は、その大きさだけでなく、中性粒子ビーム入射 (NBI) によるトロイダル角運動量入力の方向にも依存する。このモードの励起閾値以下では、プラズマのトロイダル方向のスピンアップが観測されており、これは摂動場の強さのみに依存する。それは、外部摂動場の回転方向と、NBIによって供給されるトロイダル角運動量の両方に依存しない。