AbstractSeveral materials, lenses, dry bearings and cables were exposed to a tritiated moisture environment to study the behavior of tritium contamination on candidate materials for ITER remote handling equipment. To optimize the tritium removal procedure, decontamination experiments using a gas purge with three different moisture concentrations were also performed. The surface tritium concentrations of CeO2 containing alkaline barium glass (NB), CeO2 containing lead glass (LX) and synthetic quartz (Quartz) after the exposure experiments were 7.80, 10.94 and 0.67 Bq/cm2, respectively. It was found that the tritium concentration was influenced by the compositions of the materials. The concentrations of tritium on type 831 (solid lubrication material: graphite) and type 237 (solid lubrication material: tungsten disulfate) dry bearings after the exposure experiments were 89.80 and 31.78 Bq/cm2, respectively. The tritium concentration in an electric cable tested was 5014 Bq/g after HTO moisture exposure. The tritium concentrations of lenses, LX, as typical experimental results, decreased to 2.72, 4.42 and 3.89 Bq/cm2 by purging with the moist air, dry air and dry N2, respectively. The tritium concentrations of dry bearing, type 831 dropped to 6.61, 9.42 and 10.16 Bq/cm2 by the same three decontamination treatments, respectively. A large decontamination factor of 13.6 was achieved in the case of type 831 dry bearing with a moist air purge. The tritium concentration in the electric cable was 3236 Bq/g after a moist air purge, and the decontamination factor was as low as 1.6. Therefore, decontamination with a moist air purge is not so effective for the electric cable.
トリチウム汚染の挙動を研究するため、ITER遠隔操作機器の候補材料数種をトリチウム添加湿気に曝露した。除染手順を最適化するため、3種類の異なる湿分濃度を用いたガスパージによる除染実験も実施した。曝露実験後のCeO2含有アルカリガラス(NB)、CeO2含有鉛ガラス(LX)、および合成石英(Quartz)の表面トリチウム濃度は、それぞれ7.80、10.94、0.67 Bq/cm2であった。トリチウム濃度は材料の組成に影響されることが判明した。曝露実験後の乾式軸受材料タイプ831(固体潤滑材:グラファイト)およびタイプ237(固体潤滑材:二硫化タングステン)のトリチウム濃度は、それぞれ89.80および31.78 Bq/cm2であった。試験した電纜のトリチウム濃度は、HTO湿気曝露後5014 Bq/gであった。代表的な実験結果として、レンズ(LX)のトリチウム濃度は、湿気パージ、乾燥空気パージ、乾燥N2パージの3種類の除染処理により、それぞれ2.72、4.42、3.89 Bq/cm2に低下した。乾式軸受タイプ831のトリチウム濃度は、同じ3種類の除染処理により、それぞれ6.61、9.42、10.16 Bq/cm2に低下した。タイプ831乾式軸受に湿気パージを適用した場合、除染係数は13.6という大きな値が達成された。電纜のトリチウム濃度は湿気パージ後3236 Bq/gであり、除染係数は1.6と低かった。したがって、湿気パージによる除染は電纜に対してはあまり効果的ではない。