We report the latest results on fast measurements of the electron temperature and parallel heat flux in the COMPASS tokamak scrape-off layer (SOL) and divertor region during ELMy H-mode plasmas. The system of ball-pen and Langmuir probes installed on the divertor target, the horizontal reciprocating manipulator and the fast data-acquisition system with sampling frequency rate f = 5 MSa s−1 allow us to measure the electron temperature and parallel heat flux during inter-ELM and ELM periods with high temporal resolution. The filamentary structure of the electron temperature and parallel heat flux was observed during ELMs in the SOL as well as in the divertor region. The position of the filaments within ELMs is not regular and therefore the resulting conditionally averaged ELM neglects the peak values of the electron temperature and parallel heat flux. We have found a substantial difference between the value of the radial power decay length in the inter-ELM period λq,inter = 2.5 mm and the decay length of the peak ELM heat flux λq,ELM = 13.1 mm. The decay length of the ELM energy density was found to be λE,ELM = 5.4 mm.
我々は、ELMy Hモードプラズマ中のCOMPASSトカマクのスクレイプオフ層(SOL)およびダイバータ領域における電子温度と平行熱流束の高速測定に関する最新の結果を報告する。ダイバータターゲットに設置されたボールペンプローブとラングミュアプローブ、水平往復運動マニピュレータ、およびサンプリング周波数f = 5 MSa s−1の高速データ収集システムからなるシステムにより、ELM間およびELM期間中の電子温度と平行熱流束を高い時間分解能で測定することができる。電子温度と平行熱流束のフィラメント構造は、ELM中にSOLおよびダイバータ領域の両方で観測された。ELM内のフィラメントの位置は規則的ではないため、結果として得られる条件付き平均ELMは、電子温度と平行熱流束のピーク値を無視することになる。我々は、ELM間期間の径方向パワー減衰長λ_q,inter = 2.5 mmと、ピークELM熱流束の減衰長λ_q,ELM = 13.1 mmとの間に大きな差を見出した。ELMエネルギー密度の減衰長はλ_E,ELM = 5.4 mmであることが分かった。