AbstractIn 1998, 100 g of highly tritiated carbon dust and flakes containing an estimated 1 g of Tritium were removed from the JET machine using a vacuum cleaner with a cyclone dust separator during the Remote Exchange of the divertor tiles. Two pots of flakes were filled and transferred, in drums, to the Active Gas Handling System where they were stored and ventilated to the Exhaust Detritiation System (EDS). A ventilated glovebox allowed the material to be handled safely and undergo calorimetric tritium assay. The glovebox had an air atmosphere with a continuous purge to the EDS with a facility for argon purging of isolators within the glovebox. Design features of the glovebox, operational experiences in handling tritiated carbon with a specific activity in excess of 1 TBq/g and results of the tests are discussed.
要約1998年、ダイバータタイルの遠隔交換中に、サイクロン式除塵分離器を備えた掃除機を使用して、約1gのトリチウムを含むと推定される高濃度トリチウム含有炭素粉塵およびフレーク100gがJET装置から除去された。フレークを入れた2つの容器が満たされ、ドラム缶に入れて活性ガス処理システムに移送され、そこで保管され、排気除染システム(EDS)に換気された。換気付きグローブボックスにより、材料を安全に取り扱い、熱量測定によるトリチウム分析を行うことができた。グローブボックスは空気雰囲気で、EDSへの連続パージを備え、グローブボックス内のアイソレータをアルゴンパージする設備も備えていた。グローブボックスの設計上の特徴、1TBq/gを超える比放射能を有するトリチウム含有炭素の取り扱いにおける運用経験、および試験結果について考察する。