The soft x-ray tomography diagnostic in the stellarator Wendelstein 7-X consists of twenty pinhole cameras, up–down symmetrically arranged in a poloidal, triangular cross-section of the plasma vessel. The x-ray emissivity is measured with 16 bit amplitude resolution at 2 MHz sampling rate along 360 lines-of-sight by silicon photodiode arrays. In the recent operation campaign data acquisition (DAQ) has been working reliable for the conducted plasma pulse lengths <1 min, however the DAQ system are ready for the foreseen 30 min plasma pulse lengths of upcoming campaigns. The bandwidth of the preamplifiers is ≈200 kHz and the sensitive energy range is approximately 1–12 keV. The measurements indicate the up–down symmetric emissivity distribution in the triangular poloidal cross-section. First tomographic reconstructions of different magnetic field configurations are consistent with the theoretically calculated flux surface topology.
Wendelstein 7-Xステラレーターにおける軟X線トモグラフィー診断装置は、ポロイダル断面が三角形のプラズマ容器内に上下対称に配置された20台のピンホールカメラで構成されている。X線放射率は、シリコンフォトダイオードアレイにより、360本の視線に沿って、16ビットの振幅分解能、2MHzのサンプリングレートで測定される。最近の運転キャンペーンでは、データ収集(DAQ)システムは、実施された1分未満のプラズマパルス長に対して確実に動作しているが、DAQシステムは、今後のキャンペーンで予定されている30分のプラズマパルス長にも対応可能な設計となっている。プリアンプの帯域幅は約100kHzであり、感度エネルギー範囲は約1〜12keVである。測定結果は、三角形のポロイダル断面における上下対称な放射率分布を示している。異なる磁場配位における最初のトモグラフィー再構成は、理論的に計算された磁束面トポロジーと一致している。